Table 3. F-tests and regression coefficients for relationships between imported fire ant mound and surrounding area temperature measurements and time [percentage of day (x) between sunrise and sunset] at three Mississippi study sites.
F-test for quadratic trend
Site ID Dependent variable Date df F P Equation
Nobile Mound temp Spring 2, 423 18.31 < 0.0001 y = −1.50 (±2.64) + 0.74 (±0.13) x – 0.007 (±0.001) x2
Fall 2, 423 58.53 < 0.0001 y = 10.23 (±3.62) + 1.48 (±0.15) x – 0.013 (±0.001) x2
Surrounding temp Spring 2, 423 13.23 < 0.0001 y = −0.66 (±2.65) + 0.62 (±0.13) x – 0.006 (±0.001) x2
Fall 2, 423 58.53 < 0.0001 y = 12.03 (±3.54) + 1.30 (±0.14) x – 0.012 (±0.001) x2
Clay Mound temp Spring 2, 423 91.57 < 0.0001 y = 15.62 (±1.93) + 1.08 (±0.08) x – 0.010 (±0.001) x2
Fall 2, 423 71.49 < 0.0001 y = −3.87 (±2.26) + 1.17 (±0.1.) x – 0.011 (±0.001) x2
Surrounding temp Spring 2, 423 47.75 < 0.0001 y = 15.92 (±1.89) + 0.77 (±0.08) x – 0.007 (±0.001) x2
Fall 2, 423 44.29 < 0.0001 y = −2.86 (±2.22) + 0.92 (±0.10) x – 0.009 (±0.001) x2
Levee Mound temp Spring 2, 423 16.27 < 0.0001 y = 8.36 (±2.73) + 0.77 (±0.14) x – 0.007 (±0.002) x2
Fall 2, 423 93.49 < 0.0001 y = 2.25 (±2.59) + 1.42 (±0.10) x – 0.012 (±0.001) x2
Surrounding temp Spring 2, 423 1.83 0.1614 Not significant
Fall 2, 423 76.47 < 0.0001 y = 3.96 (±2.62) + 1.29 (±0.10) x – 0.011 (±0.001) x2